Product Description
RV10203465 1KΩ Linear Taper (1KB) Control Potentiometer (Galaxy DX22 / DX2527 / RCI-2990 OEM)
Restore precision receiver attenuation, noise-free level adjustments, and exact frequency clarifier tuning to your transceiver with this genuine OEM-spec 1KΩ Linear Taper (1KB) Control Potentiometer. Sourced under factory part number RV10203465 (designated as Pot 29 on official parts control charts), this single-section rotary potentiometer features linear resistance tapering specifically engineered for front-panel RF Gain and Clarifier control circuits across Galaxy and Ranger RCI chassis platforms.
Product Specifications & Technical Data
- Galaxy / Ranger Factory Part Number: RV10203465
- Parts Chart Designator: Pot 29
- Component Type: Single Rotary Panel-Mount Potentiometer
- Nominal Resistance: 1kΩ (1,000 Ohms / Code 102)
- Resistance Taper: Linear Taper ("B" Curve / 1KB)
- Circuit Schematic Function: Front-Panel RF Gain Control / Receiver Attenuator or Fine Clarifier Tuning Control (model dependent)
- Shaft Geometry: D-Shaft (Flatted Shaft for D-Socket Front Knob Fitment)
- Mounting Configuration: Threaded Metal Bushing with Lock Washer & Hex Nut; Direct PCB Solder Pins / Wire Lugs
- Quality Standard: 100% Factory Original Equipment Manufacturer (OEM) service replacement component
- Compatible Radio Models:
- Galaxy DX22 Mobile Transceiver (RF Gain / Fine Clarifier)
- Galaxy DX2527 Base Station Transceiver
- Ranger RCI-2990 / RCI-2990DX Base Station Transceivers
- Select Connex, General, and Ranger mainboards utilizing RV10203465 (Pot 29) 1KB control potentiometers
Bench Installation & Tech Notes
- Diagnoses & Solves: Scratchy audio or static pops during RF Gain adjustment, jumpy or unstable clarifier frequency drifting, dead spots in receiver sensitivity, or worn mechanical wiper contact on original factory potentiometers.
- BENCH INSTALLATION PROCEDURE:
- Disconnect power from the transceiver chassis and remove top and bottom outer covers.
- Pull off the front-panel control knob and unscrew the outer hex retaining nut and lock washer from the threaded bushing.
- Desolder the PCB solder pins or wire harness lead connections from the potentiometer terminals using a temperature-controlled iron and desoldering pump.
- Remove the old potentiometer from the front sub-chassis frame.
- Position the new RV10203465 potentiometer into the mounting slot, ensuring proper D-shaft alignment, and secure it firmly using the retaining washer and hex nut.
- Solder the circuit connections to the terminals using 63/37 eutectic solder, ensuring clean solder joints without bridging adjacent pins.
- Reinstall the control knob, power up the transceiver, and test for smooth linear control across the full rotary rotation while checking receiver RF Gain response or clarifier center-frequency tracking.