Mirage & Ranger / RCI OEM Analog Signal & RF Power Panel Meter (Part # EX03N40556)

Restore accurate S-meter signal strength tracking and relative RF output power monitoring to your Mirage mobile transceiver with this genuine OEM Mirage / Ranger Signal & RF Power Panel Meter (Factory Part Number EX03N40556). Manufactured to original factory Ranger/RCI mechanical damping and coil specifications—not an inexpensive aftermarket substitute—this direct replacement panel meter eliminates sticky needle movements, open armature coils, or cracked lenses across classic Mirage mobile radio chassis.

⚠️ COIL POLARITY, DIAL SCALE VERIFICATION & NO-RETURN POLICY WARNINGS

• Verify Dial Scale & Chassis Match: Confirm your transceiver's original meter dial artwork and part number (EX03N40556) prior to ordering to ensure proper scale matching.
• Coil & Illumination Polarity: Carefully photograph and label the positive/negative meter coil leads (+/-) and any illumination wiring prior to desoldering to prevent reverse needle deflection.
• No-Return Policy Notice: Due to delicate jeweled meter pivot movements, fine armature coils, and soldered terminal tabs involved, genuine OEM panel meters are strictly non-returnable once installed, soldered, or powered up.

Product Specifications & Technical Data

  • Manufacturer / Brand: Mirage / Ranger / RCI (Genuine Factory OEM Service Replacement Part)
  • Factory Part Number / SKU: EX03N40556
  • Component Designation: Analog Receive Signal (S-Meter) & Relative RF Power Panel Meter Assembly
  • Function: Displays incoming receive signal strength (S-units) and relative transmit RF power output on mobile front panels
  • Mounting & Fitment: Direct Factory Front Panel Replacement for Mirage series mobile transceivers utilizing EX03N40556
  • Quality Standard: 100% Genuine Factory Original Equipment Manufacturer (OEM) Electronic Component
  • Compatible Radio Models:
    • Mirage Mobile Transceivers: Mirage MX-36HP, Mirage MX-44HP, Mirage MX-88, Mirage MX-99, and compatible Mirage mobile chassis built on Ranger/RCI platforms utilizing part number EX03N40556

Installation & Bench Notes

  • Diagnoses & Solves: Sticking or sluggish meter needle, open or burned meter armature coil, physically cracked meter lens/housing, and inaccurate S-unit or RF power readings.
  • BENCH INSTALLATION PROCEDURE:
    • Disconnect the 13.8V DC power cord and antenna coaxial cable from the transceiver chassis. Remove top and bottom cabinet covers to access the front sub-panel bay.
    • Pull off control knobs and remove front faceplate retaining screws as necessary to access the rear of the meter housing cleanly.
    • Photograph and label the positive/negative meter coil leads and any illumination lamp/LED leads attached to the existing meter before disconnecting.
    • Release the retaining bracket or mounting screws securing the faulty meter and carefully withdraw it without stressing surrounding panel wiring.
    • Seat the new EX03N40556 OEM meter squarely into the front bezel cutout and secure the retaining hardware evenly—avoiding overtightening so the case does not warp or bind the internal needle movement.
    • Connect the meter coil leads (observing strict +/- polarity) and illumination wiring according to your reference photos.
    • Apply power on the bench, verify mechanical zero-rest alignment and dial illumination, test receive S-meter deflection and transmit RF swing into a 50-ohm dummy load (adjusting internal S-meter/RF trim pots if needed), and reinstall the cabinet covers.