Cobra 2000 / Tram D300 RF PWR/ S Meters NEW

$32.95
(0) Write a Review
SKU:
MT-184

Out of stock

Product Description

Cobra 2000 GTL, Cobra 1000 GTL & Tram D300 RF Power / Signal Panel Meter — New OEM (Cobra # 320-106-9-001 / Tram # ZMTY181001)

Restore accurate receive S-unit signal tracking and forward RF output power monitoring to your classic desktop base station with this brand-new OEM Cobra 2000 GTL / Tram D300 RF Power & Signal Panel Meter (Cobra Factory Part Number 320-106-9-001 / Tram Factory Part Number ZMTY181001). Built to original factory mechanical and electrical specifications, this direct drop-in replacement meter eliminates sticky needle movements, open armature coils, or sun-faded lenses on vintage Cobra 2000 GTL and Tram D300 base stations—and also fits directly into the Cobra 1000 GTL base station as-is without modification.

⚠️ LETHAL 120V AC BASE STATION HAZARD, COIL POLARITY & NO-RETURN POLICY WARNINGS

• Lethal AC Voltage Hazard: Always unplug the 120V AC power cord and allow internal power supply filter capacitors to discharge fully before opening any base station cabinet!
• Meter Movement & Illumination Polarity: Carefully photograph and label the positive/negative meter coil leads (+/-) and meter lamp socket wiring prior to desoldering or removing your old meter to prevent reverse needle deflection.
• No-Return Policy Notice: Due to delicate jeweled meter pivot movements, fine armature coils, and soldered terminal tabs involved, new vintage OEM panel meters are strictly non-returnable once installed, soldered, or powered up.

Product Specifications & Technical Data

  • Manufacturer / Brand: Cobra / Tram (New Original Equipment Manufacturer Service Replacement Part)
  • Cobra Factory Part Number / SKU: 320-106-9-001
  • Tram Factory Part Number / Cross-Reference: ZMTY181001
  • Condition: Brand New Old Stock / OEM Replacement Assembly
  • Component Designation: Analog RF Output Power & Receive Signal Strength (S-Meter) Panel Meter
  • Function: Displays incoming receive signal strength (S-units / dB) and relative transmit RF power output on dual-meter base station front panels
  • Mounting & Fitment: Direct Factory Front Panel Replacement for Cobra 2000 GTL, Tram D300, and Cobra 1000 GTL (direct drop-in fit as-is)
  • Quality Standard: 100% Genuine Factory Original Equipment Manufacturer (OEM) Electronic Component
  • Compatible Radio Models:
    • Cobra Base Stations: Cobra 2000 GTL, Cobra 1000 GTL (fits directly as-is)
    • Tram Base Stations: Tram D300

Installation & Bench Notes

  • Diagnoses & Solves: Sluggish or dead RF/Signal meter needle, open or burned meter movement coil, physically cracked or yellowed meter lens, and inaccurate S-unit or RF power readings.
  • BENCH INSTALLATION PROCEDURE:
    • Disconnect the 120V AC power cord and antenna coaxial cable from the base station chassis. Remove the top and bottom cabinet covers to access the rear of the front panel meter bay.
    • Photograph and label the positive/negative meter coil leads and backlight lamp assembly attached to the existing meter before disconnecting.
    • Loosen or remove the retaining bracket/hardware securing the faulty meter to the front panel and carefully withdraw it without stressing adjacent clock or MOD/SWR meter wiring.
    • Seat the new 320-106-9-001 / ZMTY181001 meter squarely into the front bezel cutout and tighten the retaining hardware evenly—avoid overtightening so the meter case does not warp or bind the needle movement.
    • Connect the meter coil leads (observing strict +/- polarity) and reinstall the meter illumination lamp according to your reference photos.
    • Apply power on the bench, verify mechanical zero-rest alignment and dial lighting, test receive S-meter deflection and transmit RF power output swing into a 50-ohm dummy load (re-calibrating internal S-meter/RF power trim pots if required), and close the cabinet covers.